BRL-4060 110-480 V AC 60 A Tek Faz Güç Regülatör

BRL-4060 110-480 V AC 60 A Tek Faz Güç Regülatör
Galeri için tıklayın
  • Ürün Kodu: BRL-4060
  • Stok Durumu: Stokta var
  • $0,00
  • Vergiler Hariç: $0,00

Product Description :
Simple type without display and communication function

Rated Current: 30A & 60A
Operating Power: AC200V~440V
Output mode: Phase trigger control & Zero cross trigger control (selectable)
6 kind input signal types for optional: 0~5V, 1~5V, 0~10 V, 2~10V, 0~20mA, 4~20mA

 

Product Features :
(Some functions depending on the model)
1.) Output mode: Phase trigger control & Zero cross trigger control (selectable).
2.) 6 kind input signal types for optional: 0~5V, 1~5V, 0~10 V, 2~10V, 0~20mA, 4~20mA.
3.) Built-in fuse protection, saving the space and easier for replacement.
4.) Built-in heatsink overheat protection and temperature indicator.
5.) Built-in RS-485 communication function.

6.) Can be displayed input commands, output current, output percentage, heatsink temperature and error                                                                                                                                                             message.
7.) Can set the soft start time, overload and under load level.
8.) Has the function of error output contact and can be set and planned.
9.) Full function model includes thyristor puncture, fuse melting, heater low current and heater overload protection.

Model Explanation :

BRL-4-030

Main Power

200V ~ 440V

Rated Current

030

30A

Fuse

FWC-32A10F

060

60A

80FE

Product Specifications :

Aux Power

90~240VAC±15%, 50/60Hz (about 5W power consumption)

Main Power

Single Phase (110V, 220V, 380V, 440V)±15%, 50/60Hz

Rated Current

30A, 60A

Control Mode

Phase Control / Zero Control (selectable)

Input Signal

0~5V, 1~5V, 0~10V, 2~10V, 0-20mA, 4-20mA

Output Control Range

0~100.0%

Resolution / Linear

0.1% / 1%

Cooling Way

Nature cooling (please built-in the fan if inside temperature is overheating)

Ambient Temperature / Humidity

-10 ~ +50℃ / under 90% RH

Hi-Pot Test

AC2000V/1min. (between power, signal terminal and heatsink)

Noise Susceptibility

2KV, 5KHz

Isolation Resistor

Over 20MΩ/50V (between power, signal terminal and heatsink)

Housing Material

ABS (UL94V)